跳至主要内容

Visual Assessment of Fuzzing and/or Pilling by ICI Pilling and Snagging Tester

The viewing cabinet shall be situated in a darkened room.
Place the tested specimen and a piece of the original sample, with or without pretreatment ,centrally on
the lectern in the viewing cabinet, with the length direction vertical. If necessary use a piece of self-adhesive PVC tape to ensure correct placement. Mount the tested specimen on the left and the original sample on the right.


In order to prevent glare from the light source view each specimen from just outside the viewing cabinet, directly in front of the specimen.
Due to the subjective nature of the assessment, it is recommended that more than one observer assess the specimens.
Grade each specimen in accordance with the grading scheme given in Table1. If the grading appears between two grades, report the“half”grading as,for example,3-4.
The test result for each individual observer is the average off our specimen grades. The test result for the laboratory sample is the average of the observer grades.
Photographic assessment maybe used to support the primary descriptive method of assessment, as agreed between interested parties.
A second assessment maybe made by rotating the specimen to a position where the observed pilling is more severe. This assessment maybe used to provide data for an“extreme”condition,e.g. where a surface is being viewed along the plane of the surface.
Report any other aspect which shows deterioration in surface appearance.

Table 1 - Visual assessment
Grade
Description
5
No change.
4
Slight surface fuzzing and/or partially formed pills.
3
Moderate surface fuzzing and/or moderate pilling. Pills of varying size and density partially covering the specimen surface
2
Distinct surface fuzzing and/or distinct pilling. Pills of varying size and density partially covering a large proportion of the specimen surface.
1
Dense surface fuzzing and/or severe pilling. Pills of varying size and density partially covering the whole of the specimen surface


For more information about our testing instrument, please contact
· +86-21-6780 0179
· or leave your comments below

评论

  1. It is so useful that for your sharing. The summary is easy to understand, but I think it will be better if you add a ICI pilling box method .

    回复删除
  2. Useful testing machine for piling test

    回复删除

发表评论

此博客中的热门博文

How To Process The Elmendorf Tear Strength Test

The Elmendorf tear tester has been developed specially for the paper industry and is outstanding for simplicity of operation and high measurement accuracy. The exchangeable pendulum is equipped with a pneumatic sample clamp. The initiation and return of the pendulum, as well as sample cutting is completely automatic. The device is operated via an integrated touch screen, where the test method can be selected, specific settings can be adjusted, and, after the measurement, results and statistics can be  displayed.Each pendulum is supplied with the appropriate control weight so that, with the help of the service program, it can easily be checked for functionality and balance. The Elmendorf tear test Procedure:     Cotton fabric was taken.     Warp and weft direction of the fabric was identified.     Two strips were cut from the fabric in both directions having dimensions of 100 x 63.5 mm.     The sample was then fixed in the jaws of the ...

Correct Use Of Color Assessment Cabinet

Observation Angle: The following points are all the facilities required for the Color Assessment Cabinet , and the viewing Angle will directly affect the evaluation results. According to international standards, there are only two observable angles that can be used. They are: A, zero light source and 45 degrees observation (0 °, 45 °), the light from zero (vertical) incident Angle on the sample, sample watchers from 45 degrees. B, light source and 45 ° inclined channel 45 degrees of light source, zero observation (0 °, 45 °), the layout must use specific 45 degrees of inclined (45 ° Fixed Angle table) making from 45 degrees of light source on the samples, sample watchers from zero (vertical). The location of the 45 ° light samples: Regardless of any of the above observation methods, it is important to note that the test sample is placed in the middle of the light box as far as possible to reduce the influence of the external light source. In addition, the most important thing...

The Scratch Tester Working Principle From Qinsun LAB

The scratch test machine is used to evaluate the shear, scratch, planing, scraping and engraving performance of the material. Its applications include rigid organic materials, plastics and glass, and so on. The test parameters, such as the speed of scratches, the length of scratches, the distance between scratches and the number of lines, are the test equipment with strong applicability and convenience. scratch tester Working principle: Coating has three aspects: the action of protection, decoration, and hide the defects of products, and the three main hardness has a lot to do with paint, paint film hardness is said film one of the important properties of mechanical strength, is an important indicator of measuring coating product quality, and measure the coating hardness is an important index of the scratch resistance of determination; Coating good product in the process of packaging, transport and use will draw by hard brush, not row brush the paint film is often leave scratc...