Ozone aging chamber can release high concentration of ozone in the chamber for ozone aging test on non-metallic materials and organic materials (paint, rubber, plastic, paint, pigment, etc.).


Ozone in the Ozone aging chamber is harmful to humans?

Ozone aging chamber.jpg

If you inhale ozone, it will cause respiratory infections, and contact with ozone will aggravate existing respiratory diseases and damage people's lung function and power capacity, because ozone is very corrosive.


Ozone will also have a destructive effect on the vitamin E in human skin, which will lead to wrinkled skin, dark spots, vision loss, memory loss, and also destroy the immune system, inducing chromosomal lesions in lymphocytes and accelerating aging, and the ozone produced by the heat of the copier toner is a strong carcinogenic substance, which causes various types of cancer and cardiovascular disease.

评论

此博客中的热门博文

Determination of air permeability of a fabric-air permeability tester

Fabric air permeability is a measure to what extent it gives air passing through the fabric. Air permeability, a given area in the vertical direction of the air flow rate, a given time period, is measured by the fabric test area inside the pressure difference of the fabric. Basically, it depends on weight, thickness and porosity of fabric. The porosity of fabric is the demonstration of the air gap as a percentage within fabric. It has been important for especially the tent fabric, parachute fabric, raincoat fabric and garment, the fabric used in air bags, industrial filters and sail cloth. Moreover, when thermal properties of clothing and body interaction are taken into consideration, there has been the effect of air permeability. there is an instrument which is designed to test the air permeability of fabric on the market .it is air permeability tester . Air permeability is an important feature of fabrics (Sundaramoorthy et al., 2011) and is one of the main factors affecting the t...

Correct Use Of Color Assessment Cabinet

Observation Angle: The following points are all the facilities required for the Color Assessment Cabinet , and the viewing Angle will directly affect the evaluation results. According to international standards, there are only two observable angles that can be used. They are: A, zero light source and 45 degrees observation (0 °, 45 °), the light from zero (vertical) incident Angle on the sample, sample watchers from 45 degrees. B, light source and 45 ° inclined channel 45 degrees of light source, zero observation (0 °, 45 °), the layout must use specific 45 degrees of inclined (45 ° Fixed Angle table) making from 45 degrees of light source on the samples, sample watchers from zero (vertical). The location of the 45 ° light samples: Regardless of any of the above observation methods, it is important to note that the test sample is placed in the middle of the light box as far as possible to reduce the influence of the external light source. In addition, the most important thing...

How To Process The Elmendorf Tear Strength Test

The Elmendorf tear tester has been developed specially for the paper industry and is outstanding for simplicity of operation and high measurement accuracy. The exchangeable pendulum is equipped with a pneumatic sample clamp. The initiation and return of the pendulum, as well as sample cutting is completely automatic. The device is operated via an integrated touch screen, where the test method can be selected, specific settings can be adjusted, and, after the measurement, results and statistics can be  displayed.Each pendulum is supplied with the appropriate control weight so that, with the help of the service program, it can easily be checked for functionality and balance. The Elmendorf tear test Procedure:     Cotton fabric was taken.     Warp and weft direction of the fabric was identified.     Two strips were cut from the fabric in both directions having dimensions of 100 x 63.5 mm.     The sample was then fixed in the jaws of the ...