How to test the sun color fastness best

In all color fastness tests, testing the fabric's response to light may be one of the most important test items. Of course, the performance of the fabric in the washing, dry cleaning, rubbing, sweating and post-exposure of the fabric in different types of solutions is of vital importance to the manufacturer. But because the fabric is sensitive to light sensitivity, and difficult to predict, so accurate and reliable test is quite critical. For many manufacturers, the light fastness test is an important part of R & D and quality control.
However, it is also one of the most difficult to master the test. Because most of the material in the sunlight takes months or even years to react, so the fabric in the practical application of the environment in the natural light test is not feasible. Not to mention how many R & D departments are willing to wait patiently? Many manufacturers choose to test the lab. They simulate natural light to speed up the testing process. The most successful technique is xenon long arc radiation. This only reliable method of reconstructing natural light spectra uses a variety of different filters to reproduce special optical conditions.
Light fastness test is not just the fabric under a specific light source to observe its performance so simple. The temperature and humidity must also be taken into account, due to the fact that the temperature and humidity make the fabric more responsive to light. Thus, the light fastness tester must be able to control these environmental factors, that is, for each test to create the appropriate environmental conditions, and in the whole process to maintain a constant. In addition, if a fabric in the outdoor application, then the weather factor, especially the rain is another issue must be considered. Therefore, the equipment must contain simulated rain water sprinkler systems, as well as simulate the rest of the world's climate conditions.

评论

此博客中的热门博文

How To Process The Elmendorf Tear Strength Test

The Elmendorf tear tester has been developed specially for the paper industry and is outstanding for simplicity of operation and high measurement accuracy. The exchangeable pendulum is equipped with a pneumatic sample clamp. The initiation and return of the pendulum, as well as sample cutting is completely automatic. The device is operated via an integrated touch screen, where the test method can be selected, specific settings can be adjusted, and, after the measurement, results and statistics can be  displayed.Each pendulum is supplied with the appropriate control weight so that, with the help of the service program, it can easily be checked for functionality and balance. The Elmendorf tear test Procedure:     Cotton fabric was taken.     Warp and weft direction of the fabric was identified.     Two strips were cut from the fabric in both directions having dimensions of 100 x 63.5 mm.     The sample was then fixed in the jaws of the ...

Comparative analysis of water-cooled and air-cooled xenon lamp aging tester

Xenon lamp aging test chamber is the core component of using the box full sunlight spectrum xenon lamp tube simulation, under different environmental conditions to simulate the material aging law, through the experimental results to evaluate weather resistance of materials and products. This paper focuses on the comparative analysis of the advantages and characteristics of the water-cooled and air-cooled xenon lamp aging testing machine. Air-cooled xenon lamp aging test machine : A circular wind is used to cool the heat-trapping xenon lamp tube. Air-cooled xenon lamp tubes used in air-cooled xenon lamp aging test box, generally a typhoon cold xenon lamp aging test chamber is equipped with three air-cooled xenon lamp tubes, and table 1 air-cooled xenon lamp weather-resistant chamber equipped with xenon lamp tubes. The power of the air-cooled xenon lamp tube is generally 1.8kw, and the length of the lamp tube is 340mm compared with that of the water-cooled xenon lamp. The diameter of...

Correct Use Of Color Assessment Cabinet

Observation Angle: The following points are all the facilities required for the Color Assessment Cabinet , and the viewing Angle will directly affect the evaluation results. According to international standards, there are only two observable angles that can be used. They are: A, zero light source and 45 degrees observation (0 °, 45 °), the light from zero (vertical) incident Angle on the sample, sample watchers from 45 degrees. B, light source and 45 ° inclined channel 45 degrees of light source, zero observation (0 °, 45 °), the layout must use specific 45 degrees of inclined (45 ° Fixed Angle table) making from 45 degrees of light source on the samples, sample watchers from zero (vertical). The location of the 45 ° light samples: Regardless of any of the above observation methods, it is important to note that the test sample is placed in the middle of the light box as far as possible to reduce the influence of the external light source. In addition, the most important thing...