跳至主要内容

The Softness Tester Test Flow

Test instrument - Softness tester

Test slit width should be divided into: 5.0mm, 6.35mm, 10.0mm, 20.0mm four grades, the width of the error should not exceed ± 0.05mm.Plate-like probe Dimensions:Long: 240mmThickness: 2mmMeasuring arc radius: 1mm.Average travel speed and total stroke of the probe:Average travel speed: (1.2 ± 0.24) mm / sTotal stroke: 12 ± 0.5mm.Sample press-in depth:Pressing depth: mmSlit parallelism:The parallelism of the slit should not exceed 0.05mm.Probe Neutral:
    
After the probe into the slit probe should be symmetrical symmetry should be less than 0.05mm on both sides.Instrument Accuracy:
    
Maximum instrument range: 1000mN.
    
Load Accuracy: ± 1%.
    
Repeatability: less than 3%.Take the sample:
    
Use GB / T 450 to take the average sample.Sample handling:
    
According to GB / T 10739 temperature mission processing, and in this condition for the preparation test.



Experimental steps:
    
Press the Hand Feel Tester to adjust the instrument zero and adjust the width of the slit according to the standard deviation. Also check the width error and parallelism. Place the sample on the instrument test bed and make it as symmetrical and slit as possible. Multilayer specimens should be stacked up and down, set the instrument's peak / tracking switch to the peak position, press the test button, dashboard Shaped probe began to move. After the probe has been completed, read the measured value from the display, and then test the next sample, from the vertical and horizontal should be tested 10 data.Calculation of results:
    
The arithmetic mean of the results of the lateral test results is expressed in milliseconds and is revised to an integer.experimental report
    
The report should contain the following items
    
A) standard number;
    
B) test environmental conditions;
    
C) report the vertical and horizontal mean softness values, respectively, to the integer;
    
D) the coefficient of variation of the test results;
    
E) the number of layers to be tested;
    
F) slit width;
    
G) Deviation from standard operation.

Read more on http://www.qinsun-lab.com/

评论

此博客中的热门博文

How To Process The Elmendorf Tear Strength Test

The Elmendorf tear tester has been developed specially for the paper industry and is outstanding for simplicity of operation and high measurement accuracy. The exchangeable pendulum is equipped with a pneumatic sample clamp. The initiation and return of the pendulum, as well as sample cutting is completely automatic. The device is operated via an integrated touch screen, where the test method can be selected, specific settings can be adjusted, and, after the measurement, results and statistics can be  displayed.Each pendulum is supplied with the appropriate control weight so that, with the help of the service program, it can easily be checked for functionality and balance. The Elmendorf tear test Procedure:     Cotton fabric was taken.     Warp and weft direction of the fabric was identified.     Two strips were cut from the fabric in both directions having dimensions of 100 x 63.5 mm.     The sample was then fixed in the jaws of the ...

Correct Use Of Color Assessment Cabinet

Observation Angle: The following points are all the facilities required for the Color Assessment Cabinet , and the viewing Angle will directly affect the evaluation results. According to international standards, there are only two observable angles that can be used. They are: A, zero light source and 45 degrees observation (0 °, 45 °), the light from zero (vertical) incident Angle on the sample, sample watchers from 45 degrees. B, light source and 45 ° inclined channel 45 degrees of light source, zero observation (0 °, 45 °), the layout must use specific 45 degrees of inclined (45 ° Fixed Angle table) making from 45 degrees of light source on the samples, sample watchers from zero (vertical). The location of the 45 ° light samples: Regardless of any of the above observation methods, it is important to note that the test sample is placed in the middle of the light box as far as possible to reduce the influence of the external light source. In addition, the most important thing...

The Scratch Tester Working Principle From Qinsun LAB

The scratch test machine is used to evaluate the shear, scratch, planing, scraping and engraving performance of the material. Its applications include rigid organic materials, plastics and glass, and so on. The test parameters, such as the speed of scratches, the length of scratches, the distance between scratches and the number of lines, are the test equipment with strong applicability and convenience. scratch tester Working principle: Coating has three aspects: the action of protection, decoration, and hide the defects of products, and the three main hardness has a lot to do with paint, paint film hardness is said film one of the important properties of mechanical strength, is an important indicator of measuring coating product quality, and measure the coating hardness is an important index of the scratch resistance of determination; Coating good product in the process of packaging, transport and use will draw by hard brush, not row brush the paint film is often leave scratc...