Hydrostatic head tester is used to measure the water penetration resistance of fabrics and seams, providing a quick and accurate test result.
The specimen is secured by means of a hand operated clamp. Once the process is engaged the pressure is controlled in a slow and even motion to avoid extreme exertion on the material. The digital gauge can be read in either kPa (kiloPascal) or psi (pounds per square inch) or Bar.The test specimen is then visually observed for any evidence of water penetration.
Test Specimens
A minimum of three fabric specimens should be taken diagonally across the width of the fabric to be representative of the material.
Cut specimens at least 200x200 mm to allow properclamping.
Handle the specimens as little as possible and avoid folding or contaminating the area to be tested.
Condition the test specimens at 21 – 2°C (70 – 5°F) air at 65 – 2% RH for at least 4 h before testing.
The surface of the fabric to be ex-posed to water must be specified because different results may be obtained on the face and the back. Identify that surface on a corner of each specimen.
Test Procedure with Hydrostatic head tester:
1 、Verify the water in contact with the test specimen is regulated at 21 – 2°C (70 – 5°F).
2 、Dry the clamping surface.
3 、Clamp the specimen with the surface to be tested facing the water .
4、 Operation.
Option Hydrostatic Pressure Tester
1) Turn on the motor, press the le-ver to raise the overflow device at the rate of 10 mm/s, and close the air vent as soon as water flows from it.
2)Option Hydrostatic Head Tester
Select the gradient of 60 mbar/ min, press the start button .
5、 Disregarding water droplets that appear within approximately 3 mm adja-cent to the edge of the specimen clamp-ing ring, record the hydrostatic pressure at the moment water droplets penetrate the fabric in three different places.
The specimen is secured by means of a hand operated clamp. Once the process is engaged the pressure is controlled in a slow and even motion to avoid extreme exertion on the material. The digital gauge can be read in either kPa (kiloPascal) or psi (pounds per square inch) or Bar.The test specimen is then visually observed for any evidence of water penetration.
Test Specimens
A minimum of three fabric specimens should be taken diagonally across the width of the fabric to be representative of the material.
Cut specimens at least 200x200 mm to allow properclamping.
Handle the specimens as little as possible and avoid folding or contaminating the area to be tested.
Condition the test specimens at 21 – 2°C (70 – 5°F) air at 65 – 2% RH for at least 4 h before testing.
The surface of the fabric to be ex-posed to water must be specified because different results may be obtained on the face and the back. Identify that surface on a corner of each specimen.
Test Procedure with Hydrostatic head tester:
1 、Verify the water in contact with the test specimen is regulated at 21 – 2°C (70 – 5°F).
2 、Dry the clamping surface.
3 、Clamp the specimen with the surface to be tested facing the water .
4、 Operation.
Option Hydrostatic Pressure Tester
1) Turn on the motor, press the le-ver to raise the overflow device at the rate of 10 mm/s, and close the air vent as soon as water flows from it.
2)Option Hydrostatic Head Tester
Select the gradient of 60 mbar/ min, press the start button .
5、 Disregarding water droplets that appear within approximately 3 mm adja-cent to the edge of the specimen clamp-ing ring, record the hydrostatic pressure at the moment water droplets penetrate the fabric in three different places.