How To Classify Face Masks ?

       Mask is a kind of sanitary products, generally refers to wear in the mouth and nose position used to filter the air into the mouth and nose, in order to block harmful gas, smell, droplets in and out of the wearer's mouth and nose appliances, made of non-woven cloth.Masks have a certain filtering effect on the air into the lungs, in the respiratory tract infection epidemic, dust and other pollution in the environment, wearing masks has a very good effect.
         




       Masks can be divided into the following categories according to the nature of use:
Civil daily protective mask: it is mainly used for filtering out particulate matter in the air pollution environment in daily life.According to its protection level can be subdivided into: anti-haze mask and cotton mask two types.Anti-haze mask is used to effectively filter PM2.5 in the haze weather, its main characteristics are good filtering performance, but its permeability is poor;Cotton mask is a modern practical more extensive mask, its main characteristics are warm, good permeability and other characteristics, but it can only filter the larger particles,  the effect of dust and bacteria is almost no.

      Surgical mask: it has good filtration effect on bacteria and viruses, breathable, comfortable and clean, and is widely used by modern doctors.The surgical mask is subdivided into three types according to its usage: disposable surgical mask, surgical mask and medical protective mask.Disposable surgical mask is suitable for wearing and blocking the exhalation or ejection of pollutants in the oral cavity and nasal cavity in the general medical environment.Medical surgical mask is suitable for disposable mask worn by clinical medical personnel during invasive operation (this kind of mask is generally divided into three layers: internal water absorption layer, intermediate filtration layer and outer waterproof layer);Medical respirator is suitable for the medical working environment, filtering the particulate matter in the air, blocking droplets, blood, body fluids, secretions and other self-absorption filter medical respirator.

    Industrial dust mask: characteristic is inspiratory parts have a multi-layer protector or multilayer sandwich, commonly used in specific jobs, like paint, cement, micrometeorology, work environments, such as processing and iron filings, smoke when there is a lot of dust, can effective breathing dust protection used, is a special type of work within a unit to use national mandatory requirements.According to the filtration performance, it can be divided into KN and KP .

A Masks test machines manufacturer- Qinsunlab is a company who specialize in manufacturing professional test instruments for masks testing .


评论

此博客中的热门博文

How To Process The Elmendorf Tear Strength Test

The Elmendorf tear tester has been developed specially for the paper industry and is outstanding for simplicity of operation and high measurement accuracy. The exchangeable pendulum is equipped with a pneumatic sample clamp. The initiation and return of the pendulum, as well as sample cutting is completely automatic. The device is operated via an integrated touch screen, where the test method can be selected, specific settings can be adjusted, and, after the measurement, results and statistics can be  displayed.Each pendulum is supplied with the appropriate control weight so that, with the help of the service program, it can easily be checked for functionality and balance. The Elmendorf tear test Procedure:     Cotton fabric was taken.     Warp and weft direction of the fabric was identified.     Two strips were cut from the fabric in both directions having dimensions of 100 x 63.5 mm.     The sample was then fixed in the jaws of the ...

Comparative analysis of water-cooled and air-cooled xenon lamp aging tester

Xenon lamp aging test chamber is the core component of using the box full sunlight spectrum xenon lamp tube simulation, under different environmental conditions to simulate the material aging law, through the experimental results to evaluate weather resistance of materials and products. This paper focuses on the comparative analysis of the advantages and characteristics of the water-cooled and air-cooled xenon lamp aging testing machine. Air-cooled xenon lamp aging test machine : A circular wind is used to cool the heat-trapping xenon lamp tube. Air-cooled xenon lamp tubes used in air-cooled xenon lamp aging test box, generally a typhoon cold xenon lamp aging test chamber is equipped with three air-cooled xenon lamp tubes, and table 1 air-cooled xenon lamp weather-resistant chamber equipped with xenon lamp tubes. The power of the air-cooled xenon lamp tube is generally 1.8kw, and the length of the lamp tube is 340mm compared with that of the water-cooled xenon lamp. The diameter of...

Correct Use Of Color Assessment Cabinet

Observation Angle: The following points are all the facilities required for the Color Assessment Cabinet , and the viewing Angle will directly affect the evaluation results. According to international standards, there are only two observable angles that can be used. They are: A, zero light source and 45 degrees observation (0 °, 45 °), the light from zero (vertical) incident Angle on the sample, sample watchers from 45 degrees. B, light source and 45 ° inclined channel 45 degrees of light source, zero observation (0 °, 45 °), the layout must use specific 45 degrees of inclined (45 ° Fixed Angle table) making from 45 degrees of light source on the samples, sample watchers from zero (vertical). The location of the 45 ° light samples: Regardless of any of the above observation methods, it is important to note that the test sample is placed in the middle of the light box as far as possible to reduce the influence of the external light source. In addition, the most important thing...