Interpretation of The Principle of Five finger Scratching

Scratch resistance test is a lot of materials need to do a test
indicator.Currently used on the scratch resistance testing methods are many, but the principle is basically similar. The following focus on the interpretation of the next five fingers scratch method. This test method requires the use of the instrument for the five fingers scratch tester. The scratch tester uses tungsten carbide as a scratch to accurately detect surface wear caused by unconventional defined physical form (eg scraping, grasping, planing, etc.). Take the initiative to detect the car, the outer trim in the smooth, texture of the plastic pieces of wear resistance.
Designed based on the automotive industry standard technical requirements, there are usually five contacts. Five fingers scratch tester instrument bracket supports five independent spline rods, so that the needle can be loaded with continuous vertical force. The handle of the bracket controls the height of the cantilever, and the five brackets allow one or more of the cantilevers to move to a non-obstructive place, so that they can not touch the sample in the test.
The test sample is fixed on a compressed air driven test platform. Five independent shaft scraping fingers that can be replaced with different weights and optional scraping fingers, constant vertical acting on the test sample surface. The scraper is mounted on a hard bench, and the operator can hold the specified scraper in a balanced position by means of a bracket so that the irregularly sized sample can also be tested.
Five fingers scratch / scratch tester is designed for plastic material assessment, hard material wear, paint, ink, soft metal, oil carpet and other material testing.
Five fingers scratch / scratch tester principle: This test method is used to test the surface material resistance from the scratch caused by the ability to hurt. According to the material may be used in contact with the nails or other hard objects, the use of different materials, scraper, in accordance with the provisions of the direction, travel, speed, with a certain pressure on the sample surface, scraping the head and the sample to do relative movement, Unidirectional, non-reciprocating straight line scratching the track, scratching between the parallel. Final evaluation of the scratched sensory grade of the material, the color difference between the scratched area and the unscrewed area, or the minimum wiping force when the surface of the sample is damaged.The instrument consists of motor drive mechanism, scraping components, sample clamping fixtures and other components. Scratch components include scraper brackets, scraping fingers, scraping finger sets, presses (weights and weight support bars), and the like.
Five fingers scratch tester instrument can be free to install, replace, disassemble different specifications of the scraping fingers, can be carried out under different load uniform one-way linear scratches the movement. The instrument uses embedded system, man-machine interface operation of the test process for automatic control, the use of precision servo motor, ball screw drive, for the relevant standards in the scratch speed control accuracy has a decisive role. The use of tungsten carbide material to do scratching the instrument to increase the service life, the instrument using aluminum alloy and stainless steel appearance simple and lightweight and corrosion-resistant.

评论

此博客中的热门博文

How To Process The Elmendorf Tear Strength Test

The Elmendorf tear tester has been developed specially for the paper industry and is outstanding for simplicity of operation and high measurement accuracy. The exchangeable pendulum is equipped with a pneumatic sample clamp. The initiation and return of the pendulum, as well as sample cutting is completely automatic. The device is operated via an integrated touch screen, where the test method can be selected, specific settings can be adjusted, and, after the measurement, results and statistics can be  displayed.Each pendulum is supplied with the appropriate control weight so that, with the help of the service program, it can easily be checked for functionality and balance. The Elmendorf tear test Procedure:     Cotton fabric was taken.     Warp and weft direction of the fabric was identified.     Two strips were cut from the fabric in both directions having dimensions of 100 x 63.5 mm.     The sample was then fixed in the jaws of the ...

Comparative analysis of water-cooled and air-cooled xenon lamp aging tester

Xenon lamp aging test chamber is the core component of using the box full sunlight spectrum xenon lamp tube simulation, under different environmental conditions to simulate the material aging law, through the experimental results to evaluate weather resistance of materials and products. This paper focuses on the comparative analysis of the advantages and characteristics of the water-cooled and air-cooled xenon lamp aging testing machine. Air-cooled xenon lamp aging test machine : A circular wind is used to cool the heat-trapping xenon lamp tube. Air-cooled xenon lamp tubes used in air-cooled xenon lamp aging test box, generally a typhoon cold xenon lamp aging test chamber is equipped with three air-cooled xenon lamp tubes, and table 1 air-cooled xenon lamp weather-resistant chamber equipped with xenon lamp tubes. The power of the air-cooled xenon lamp tube is generally 1.8kw, and the length of the lamp tube is 340mm compared with that of the water-cooled xenon lamp. The diameter of...

Correct Use Of Color Assessment Cabinet

Observation Angle: The following points are all the facilities required for the Color Assessment Cabinet , and the viewing Angle will directly affect the evaluation results. According to international standards, there are only two observable angles that can be used. They are: A, zero light source and 45 degrees observation (0 °, 45 °), the light from zero (vertical) incident Angle on the sample, sample watchers from 45 degrees. B, light source and 45 ° inclined channel 45 degrees of light source, zero observation (0 °, 45 °), the layout must use specific 45 degrees of inclined (45 ° Fixed Angle table) making from 45 degrees of light source on the samples, sample watchers from zero (vertical). The location of the 45 ° light samples: Regardless of any of the above observation methods, it is important to note that the test sample is placed in the middle of the light box as far as possible to reduce the influence of the external light source. In addition, the most important thing...