 Bacterial & Viral Filtration Efficiency (BFE/VFE) Tester


Bacterial Filtration Efficiency Tester is to determine the bacterial filtration efficiency (BFE) of medical face mask materials by employing a ratio of the upstream bacterial challenge to downstream residual concentration of the tested medical face mask materials. The control console adopts microcomputer control system to coordinate and control the work of aerosol generation system, transmission system, negative pressure cabinet and sampling system, and display the working status in real time. The whole measurement work is completed automatically.

Mask Bacterial Filtration Efficiency Tester Standards:
 
YY 0469-2004 Technical requirements for surgical mask
BS EN 14683-2014 Medical face masks - Requirements and test methods
ASTM F2100-2019 Standard Specification for Performance of Materials Used in Medical Face Masks            
ASTM F2101 Standard Test Method for Evaluating the Bacterial Filtration Efficiency (BFE) of Medical Face Mask Materials, Using a Biological Aerosol of Staphylococcus aureus

Masks Bacterial Filtration Efficiency (BFE) Tester Parameter:


Cabinet negative pressureData can be downloaded via usb flash drive
Data storage capacityData can be downloaded via usb flash drive
mass flow controller0-20L/min,resolution:0.1 L/min
Peristaltic pump flow(0.01~3.0)mL/min
High efficiency air filter characteristicsThe filtration efficiency of particles above 0.3um is ≥99.99%
Median mass diameter of aerosol generatorThe average particle diameter was (3.0±0.3)μm,Geometric standard deviation≤1.5
Two-channel 6-stage Anderson sampler captures particle sizeⅠclass>7μm,class(4.7~7)μm,Ⅲ class(3.3~4.7)μm, class(2.1~3.3)μm,class(1.1~2.1)μm, class(0.6~1.1)μm
Fog chamber specifications(600×80×5)mm
Total number of positive quality control sampler particles(2200±500)cfu
Ventilation flow of negative pressure system800m³/min
Operation room dimension(740×940×440)mm
dimensionAbout 1200×650×2100mm
Instrument noise<65Db(A)
weight120kg
power consumption<1500W

Mask Bacterial Filtration Efficiency Tester

评论

此博客中的热门博文

Determination of air permeability of a fabric-air permeability tester

Fabric air permeability is a measure to what extent it gives air passing through the fabric. Air permeability, a given area in the vertical direction of the air flow rate, a given time period, is measured by the fabric test area inside the pressure difference of the fabric. Basically, it depends on weight, thickness and porosity of fabric. The porosity of fabric is the demonstration of the air gap as a percentage within fabric. It has been important for especially the tent fabric, parachute fabric, raincoat fabric and garment, the fabric used in air bags, industrial filters and sail cloth. Moreover, when thermal properties of clothing and body interaction are taken into consideration, there has been the effect of air permeability. there is an instrument which is designed to test the air permeability of fabric on the market .it is air permeability tester . Air permeability is an important feature of fabrics (Sundaramoorthy et al., 2011) and is one of the main factors affecting the t...

Correct Use Of Color Assessment Cabinet

Observation Angle: The following points are all the facilities required for the Color Assessment Cabinet , and the viewing Angle will directly affect the evaluation results. According to international standards, there are only two observable angles that can be used. They are: A, zero light source and 45 degrees observation (0 °, 45 °), the light from zero (vertical) incident Angle on the sample, sample watchers from 45 degrees. B, light source and 45 ° inclined channel 45 degrees of light source, zero observation (0 °, 45 °), the layout must use specific 45 degrees of inclined (45 ° Fixed Angle table) making from 45 degrees of light source on the samples, sample watchers from zero (vertical). The location of the 45 ° light samples: Regardless of any of the above observation methods, it is important to note that the test sample is placed in the middle of the light box as far as possible to reduce the influence of the external light source. In addition, the most important thing...

Comparative analysis of water-cooled and air-cooled xenon lamp aging tester

Xenon lamp aging test chamber is the core component of using the box full sunlight spectrum xenon lamp tube simulation, under different environmental conditions to simulate the material aging law, through the experimental results to evaluate weather resistance of materials and products. This paper focuses on the comparative analysis of the advantages and characteristics of the water-cooled and air-cooled xenon lamp aging testing machine. Air-cooled xenon lamp aging test machine : A circular wind is used to cool the heat-trapping xenon lamp tube. Air-cooled xenon lamp tubes used in air-cooled xenon lamp aging test box, generally a typhoon cold xenon lamp aging test chamber is equipped with three air-cooled xenon lamp tubes, and table 1 air-cooled xenon lamp weather-resistant chamber equipped with xenon lamp tubes. The power of the air-cooled xenon lamp tube is generally 1.8kw, and the length of the lamp tube is 340mm compared with that of the water-cooled xenon lamp. The diameter of...