 Medical Face Mask Particle Protection Effect Meter


Medical face mask particle protection testercan be used to detect the filtration efficiency and resistance of particles such as masks and filter materials in medical device inspection center, face masks and melt blown fabrics. The tester with particle generator can provide sodium chloride particles and paraffin oil particles.

Medical Face Mask Particle Protection Tester Echnical Features:

It is equipped with a special salt aerosol generator, which can generate aerosols of specific particle size and concentration.

Automatic control of aerosol generation and automatic calculation of capture efficiency and mask airflow resistance, reducing human intervention.

Equipped with a series of special clamps, suitable for the detection of various masks.

Built-in high life photometer module, accumulated sampling time, prompt optical path cleaning.

Built-in high-precision electronic flowmeter and high-performance sampling pump to ensure flow stability.

Built-in compressor with automatic pneumatic clamping function.Equipped with an anti-static device.

The color high-definition LCD touch screen is adopted, which makes the content more intuitive and the operation more convenient.
No leakage of aerosol, and a high degree of personal protection.

Automatic infrared anti-pinch protection function to protect personnel safety.
 
Medical Face Mask Particle Protection Tester Standards:

EN 143 Protection device, particle filter requirement, test, mark

EN 149 Respiratory protection device, microparticle filter with half mask required test mark

NIOSH 42 CFR Part 84 Respiratory protection device

GB/T 2626 Self - priming filter type particulate respirator of Respiratory protective equipment

GB/T 32610 Technical specification for daily protective masks



评论

此博客中的热门博文

How To Process The Elmendorf Tear Strength Test

The Elmendorf tear tester has been developed specially for the paper industry and is outstanding for simplicity of operation and high measurement accuracy. The exchangeable pendulum is equipped with a pneumatic sample clamp. The initiation and return of the pendulum, as well as sample cutting is completely automatic. The device is operated via an integrated touch screen, where the test method can be selected, specific settings can be adjusted, and, after the measurement, results and statistics can be  displayed.Each pendulum is supplied with the appropriate control weight so that, with the help of the service program, it can easily be checked for functionality and balance. The Elmendorf tear test Procedure:     Cotton fabric was taken.     Warp and weft direction of the fabric was identified.     Two strips were cut from the fabric in both directions having dimensions of 100 x 63.5 mm.     The sample was then fixed in the jaws of the ...

Comparative analysis of water-cooled and air-cooled xenon lamp aging tester

Xenon lamp aging test chamber is the core component of using the box full sunlight spectrum xenon lamp tube simulation, under different environmental conditions to simulate the material aging law, through the experimental results to evaluate weather resistance of materials and products. This paper focuses on the comparative analysis of the advantages and characteristics of the water-cooled and air-cooled xenon lamp aging testing machine. Air-cooled xenon lamp aging test machine : A circular wind is used to cool the heat-trapping xenon lamp tube. Air-cooled xenon lamp tubes used in air-cooled xenon lamp aging test box, generally a typhoon cold xenon lamp aging test chamber is equipped with three air-cooled xenon lamp tubes, and table 1 air-cooled xenon lamp weather-resistant chamber equipped with xenon lamp tubes. The power of the air-cooled xenon lamp tube is generally 1.8kw, and the length of the lamp tube is 340mm compared with that of the water-cooled xenon lamp. The diameter of...

Correct Use Of Color Assessment Cabinet

Observation Angle: The following points are all the facilities required for the Color Assessment Cabinet , and the viewing Angle will directly affect the evaluation results. According to international standards, there are only two observable angles that can be used. They are: A, zero light source and 45 degrees observation (0 °, 45 °), the light from zero (vertical) incident Angle on the sample, sample watchers from 45 degrees. B, light source and 45 ° inclined channel 45 degrees of light source, zero observation (0 °, 45 °), the layout must use specific 45 degrees of inclined (45 ° Fixed Angle table) making from 45 degrees of light source on the samples, sample watchers from zero (vertical). The location of the 45 ° light samples: Regardless of any of the above observation methods, it is important to note that the test sample is placed in the middle of the light box as far as possible to reduce the influence of the external light source. In addition, the most important thing...